Series UT Transmitters
Specifications - Installation and Operating Instructions
Bulletin L-UT
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/872-9057 e-mail: [email protected]
Vedere la pagina 0
1 2 3 4 5 6 ... 19 20

Sommario

Pagina 1 - DWYER INSTRUMENTS, INC

Series UT TransmittersSpecifications - Installation and Operating InstructionsBulletin L-UTDWYER INSTRUMENTS, INC. Phone: 219/879-8000 www.dwyer-inst.

Pagina 2

Setting the Series UTC Relay ValuesYou can set the relays to five different configuration modes: Level, Distance andFlow (where applicable), Volume an

Pagina 3

Setting Relay 4 to Report Errors This mode enables you to use the relay as a trigger to set on an alarm or siren incase the unit produces inaccurate m

Pagina 4

To Set the Relay Values for Level or Distance:Setting the 20 mA/4 mA LevelsSeries UT enables you to set height, volume or flow values to be used as 20

Pagina 5

Setting the Application TypeThe Series UT main menu displays (by default) LIQUID for models intended forliquid. Series UT model intended

Pagina 6

The scan distance function is accessed from the default screen. AUTO. CAL isdisplayed at the base of the display screen during the

Pagina 7

To Select the Flow Measurement Settings:Open Channels Flow MeasurementsThe flume/weir type code methodology used when setting up open channe

Pagina 8

Trapezoidal (Cipolletti) Sharp-Crested Weir (Type 3)Khafagi-Venturi Flume (Type 5)Parshall Flume (Type 6)Palmer Bowlus Flume Trapezoidal Throat Cross-

Pagina 9

H Flume (Type 8)Neyrpic Venturi Flume/Long-Base Weir (Type 9)Long-Base WeirFlumes/Weirs - American StandardRectangular Suppressed Sharp-Crested Weir (

Pagina 10

V-Notch (Triangular) Sharp-Crested Weir (Type 4)Parshall Flume (Type 5)Palmer Bowlus Flume Trapezoidal Throat Cross-Selection (Type 6)H Flume (Type 7)

Pagina 11

Leopold-Lagco Flume(Type 8)Chapter 5: Additional FeaturesThis chapter describes the functions available in Series UT’s additional menu.The additional

Pagina 12

Table of ContentsChapter 1. Introducing Series UTSensor Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 13

Appendix A: Series UT RangesThis appendix provides the maximum and minimum permitted values for the mainmenu functions in the Series UTS and Series UT

Pagina 14

Chapter 1: IntroductionSeries UT is a non contact, ultrasonic, continuous level measurement instrumentthat is able to provide accurate meas

Pagina 15

SPECIFICATIONSSERIES UTCService: Compatible liquids.Wetted Materials: ECTFE.Ranges: (Sensor Dependent)Short Range: 1.3 to 39.4 ft (0.4 to 12 m);Standa

Pagina 16

Flexible CableFlexible sensor cables are supplied with 16.4 ft/5 m loose-end cable. However, theycan be modified to fit longer length than 16.4 ft/5 m

Pagina 17

Sensor PositioningWhen installing the sensor, ensure that it is:• Mounted above the dead-zone area (Blind Zone) (blocking distance). • Positioned at l

Pagina 18

Wiring the Sensor CableSensor cable specifications: 5 wires, 0.75 mm2overall shielded.After the sensor is installed on the tank, the free en

Pagina 19

Using the Series UT Function ButtonsThe function buttons are used to perform various operations, summarized in thefollowing table. Modifying N

Pagina 20

temporarily while Series UT is taking a reading. You can refresh the reading by pressing the ENT and BACK buttonssimultaneously. Setting Main